Panametrics PanaFlare XGF1100 – ultrasonic flare gas flow meter

ULTRASONIC FLARE GAS FLOW METER
Panametrics XGF1100 ultrasonic flare gas flow meter

The Panametrics PanaFlare XGF1100 is the latest generation of ultrasonic transmitter for flare gas. Besides velocity, volumetric and mass flow and molecular weight it provides net heating value (NHV) and combustion/destruction efficiency (CE/DRE). The manufacturer states API 22.3 compliance.

Typical uses: flare and vent gas in refineries, petrochemicals and production, hydrocarbon gases, biogas and digester gas. The measurement supports emission balancing and reporting.

How the XGF1100 measures

The meter uses Correlation Transit-Time with wetted transducers. From the speed of sound it determines the average molecular weight and, with temperature and pressure, calculates mass flow – without a composition analyzer.

The transmitter has Ethernet and RS485 (Modbus) as standard, a PanaView Plus web server and optional HART 7 or Foundation Fieldbus. Up to 4 paths optional.

Panametrics

Benefits:

  • 4000:1 turndown, up to 120 m/s
  • Mass flow and molecular weight
  • No pressure loss, no moving parts
  • Pipes 80 mm až 3 250 mm
  • Explosion-proof Ex d IIC

Technical specifications

Measurement principleCorrelation Transit-Time, 1–2 paths (optional up to 4)
Velocity range±100 m/s bidirectional; extended 0.03 to 120 m/s; 4000:1
AccuracyMass flow ±2.0 to ±3.0%; velocity ±1.5 to ±2.5%; molecular weight ±1.8 to ±2.0%; NHV ±2.0 to ±5.0%
Repeatability±0.5% (0.3 to 120 m/s)
Pipe size80 to 3,250 mm
Gas temperature−55 to 150 °C (NT)
Pressure−0.14 to 103 barg
Outputs1× 4–20 mA (NAMUR NE43), 1× digital (alarm/pulse/frequency); optional extra I/O, RTD
CommunicationRS485 (Modbus), Ethernet 10/100; optional HART 7, Foundation Fieldbus FISCO
Power100–240 VAC or 12–28 VDC; 15 W max.
TransmitterAluminium or 316 SS, Type 4X / IP66; −40 to 65 °C
Hazardous areaEx d IIC T6 Gb, IECEx and ATEX II 2G IP66; US/CAN Cl 1, Div 1, Grp B, C, D T6 (per datasheet)

Accuracy depends on pipe size, number of paths, transducer type and installation.

Options

  • Up to 4 paths
  • NHV and CE/DRE calculation
  • 100 kHz transducers, stainless transmitter

Previous generations: XGF868i and GF868.

Flare control, combustion efficiency and real-time emissions: Panametrics flare.IQ.

Why buy the XGF1100 from INTECH CONTROL

INTECH CONTROL is the official sales, technical and service representative of PANAMETRICS in Slovakia and Hungary. We assess the flare header measuring point, specify transducers and number of paths, and provide delivery, installation support and commissioning.

Send us the flare header size, gas composition, pressure, temperature and flow range – we will propose the XGF1100 configuration.

Send an inquiry Datasheet (PDF) All contacts

Technical data: Panametrics datasheet PANA100DS Rev. 2 (04/2026) — © Panametrics LLC. Prepared by INTECH CONTROL, the official Panametrics representative in Slovakia and Hungary.

Top