+421 / 2 / 45 64 08 69 firma@intechcontrol.sk

Panametrics DigitalFlow XGF868i – ultrasonic flare gas flow meter

ULTRASONIC FLARE GAS FLOW METER
Panametrics XGF868i ultrasonic flare gas flow meter

The Panametrics DigitalFlow XGF868i is a compact explosion-proof transmitter for ultrasonic mass flow measurement of flare gas with two-path averaging. It also calculates average molecular weight and optionally net heating value (NHV).

Typical uses: flare and vent gas in refineries, petrochemicals and production, hydrocarbon gases, biogas and digester gas. The measurement supports emission balancing and reporting.

How the XGF868i measures

The meter uses Correlation Transit-Time with wetted transducers. From the speed of sound it determines the average molecular weight and, with temperature and pressure, calculates mass flow – without a composition analyzer.

The compact transmitter with 2 × 16 character display and magnetic keypad has two 4–20 mA outputs with HART 7, two inputs for pressure and temperature and optional Modbus, Ethernet or Foundation Fieldbus.

Panametrics

Benefits:

  • 4000:1 turndown, up to 120 m/s
  • Mass flow and molecular weight
  • No pressure loss, no moving parts
  • Pipes 100 mm až 3 m
  • Explosion-proof Ex d IIC

Technical specifications

Measurement principleCorrelation Transit-Time, 2 paths, wetted transducers
Velocity range±100 m/s bidirectional; extended 0.03 to 120 m/s; 4000:1
AccuracyMass flow ±2.3 to ±4.0%; velocity ±1.0 to ±2.0%; molecular weight ±1.8 to ±2%
Repeatability±0.5% (0.3 to 120 m/s)
Pipe size100 mm to 3 m
Gas temperatureNT −55 to 150 °C; LT −220 to 100 °C; HT −50 to 250 °C; XT −180 to 300 °C
Pressure−0.14 to 103 barg
Outputs and inputs2× 0/4–20 mA with HART 7; 2× 4–20 mA inputs (or RTD input); optional 2 frequency outputs
CommunicationRS232; optional Modbus RS485/TCP, Ethernet, OPC, Foundation Fieldbus
Power100–240 VAC or 12–28 VDC; 20 W max.
TransmitterAluminium or stainless, Type 4X / IP66; −40 to 60 °C
Hazardous areaATEX II 2 G Ex db IIC T6…T2 Gb IP66, IECEx Ex db IIC T6…T2 Gb IP66; Class I, Div. 1 (per datasheet)

Accuracy depends on pipe size, number of paths, transducer type and installation.

Options

  • Net heating value (NHV)
  • Stainless transmitter
  • PanaView software

Latest generation with combustion efficiency: Panametrics PanaFlare XGF1100.

Flare control, combustion efficiency and real-time emissions: Panametrics flare.IQ.

Why buy the XGF868i from INTECH CONTROL

INTECH CONTROL is the official sales, technical and service representative of PANAMETRICS in Slovakia and Hungary. We assess the flare header measuring point, specify transducers and number of paths, and provide delivery, installation support and commissioning.

Send us the flare header size, gas composition, pressure, temperature and flow range – we will propose the XGF868i configuration.

Send an inquiry Datasheet (PDF) All contacts

Technical data: Panametrics datasheet PANA060DS Rev. 16 (09/2025) — © Panametrics LLC. Prepared by INTECH CONTROL, the official Panametrics representative in Slovakia and Hungary.

Top