by Bohuslav Bobrik Bohuslav Bobrik
APPLICATION NOTE
Biogas plant with digesters – bio-methane upgrading

Multi-Stream Gas Analysis in Bio-Methane Upgrading

Biogas is gaining ground as a renewable alternative to natural gas. Once upgraded to bio-methane, it can be injected into the gas grid and used for home heating, cooking and as a fuel.

Application

To be accepted into the grid, the gas must have a high calorific value. Contaminants such as CO2, O2 and H2S therefore have to be removed first.

Oxygen range0–2 % O2
Carbon dioxide range90–100 % in methane background
Methane range90–100 % in CO2 background
Hydrogen sulfide0–10 ppm H2S
Operating temperature−5 °C (23 °F) to 50 °C (122 °F)
Operating pressureRegulated to 101.3 kPa (14.7 psia)
Panametrics

Benefits:

  • Continuous measurement of all gas streams
  • Sensors can be calibrated in minutes
  • Rugged design for many years of service
  • Global hazardous area certifications for all devices
Panametrics multi-stream gas analysis sample system

Challenge

Oxygen is monitored in the gas produced by the decomposition of waste. Methane is flammable in air at concentrations between 5 % and 15 %, so the oxygen content must be kept below 2 % for the biogas to be transported safely through pipelines.

Hydrogen sulfide is removed by carbon filters and must be below 10 ppm before the gas enters the network. Carbon dioxide is measured as it is separated from the bio-methane, and the methane purity of the cleaned gas has to be verified before grid injection. All of these measurements take place in hazardous areas.

Solution

The Panametrics XMO2pro transmitter measures oxygen using thermoparamagnetic technology, while the Panametrics XMTCpro transmitter uses thermal conductivity to measure carbon dioxide and methane. H2S is measured with a fuel cell sensor. All analyzers are integrated into a single sample system that regulates the pressure and flow of each gas stream and ensures accurate measurement of:

  • O2 and H2S in the cleaned biogas stream
  • Methane content in the CO2 off-gas
  • CO2 impurities in the methane stream
  • Methane purity
Bio-methane upgrading process diagram

Bio-methane upgrading process

Panametrics XMO2pro Oxygen Analyzer

Datasheet (PDF) Panametrics XMO2pro

Panametrics XMTCpro Thermal Conductivity Gas Analyzer

Datasheet (PDF) Panametrics XMTCpro

Source: Panametrics Application Note PANA038AN (panametrics.com) — © Panametrics LLC. Localized and prepared by INTECH CONTROL, official Panametrics representative for Slovakia and Hungary.