+421 / 2 / 45 64 08 69 firma@intechcontrol.sk

Panametrics AquaTrans AT600 – Clamp-On Ultrasonic Flow Meter

CLAMP-ON FLOW METER FOR LIQUIDS – PERMANENT INSTALLATION
Panametrics AquaTrans AT600 ultrasonic flow meter with transmitter and clamp-on transducers

The Panametrics AquaTrans AT600 is a complete single-channel clamp-on ultrasonic flow meter for liquids in full pipes. The transducers are mounted on the outside of the pipe – no cutting, no pressure loss and no moving parts. It is a cost-effective solution for permanent water flow measurement that requires no intervention in the process.

Typical uses: potable water, wastewater and sewage, discharge and treated water, cooling and heating water, and irrigation. It measures on pipes from 15 to 7,600 mm outside diameter made of metals and most plastics.

How the AT600 measures

The AT600 uses the patented Correlation Transit-Time method. Two clamp-on transducers alternately transmit and receive an ultrasonic signal with and against the flow; from the difference in transit times the transmitter determines flow velocity and direction, volumetric and totalized flow. The measurement automatically adapts to changing fluid properties.

Installation takes four steps – straps, fixture, spacing and lock. The transducers use a permanent solid couplant, so there is no gel to renew. The transmitter has a graphic display, a six-button keypad and a green/red status light.

Panametrics

Benefits:

  • Cost-effective, non-intrusive measurement
  • Four-step installation
  • No moving parts, no pressure loss
  • ±1% of reading accuracy (DN 50 and larger)
  • 4–20 mA, HART and Modbus outputs
  • Water-calibrated with certificate

Technical specifications

Measurement principleCorrelation Transit-Time, clamp-on ultrasonic transducers
FluidsAcoustically conductive liquids, including most clean liquids and liquids with small amounts of entrained solids or gas bubbles; full pipe
Velocity range−12.19 to 12.19 m/s, bidirectional; 400:1 turndown
Accuracy±1% of reading for DN 50 and larger, ±2% of reading below DN 50 (at velocities above 0.3 m/s); ±0.5% with field calibration
Repeatability±0.2% of reading
Measured valuesVelocity, volumetric flow, totalized flow
Channels1
Pipe size15 to 7,600 mm (outside diameter)
Pipe materialAll metals and most plastics; concrete, composite, highly corroded or lined pipes on consultation
Fluid temperature−40 to 150 °C as standard; up to 230 °C depending on transducer
Outputs4–20 mA (NAMUR NE43), optionally with HART 7 or Modbus RS485; frequency, pulse or alarm output depending on configuration
Power85–265 VAC, 50/60 Hz; optional 12–28 VDC; 5 W
Display and keypadGraphic LCD 128 × 64 pixels, 6-button keypad, status light
TransmitterEpoxy-coated aluminium enclosure, Type 4X / IP67; 168 × 128 × 61 mm; 1.5 kg
Operating temperature−20 to 55 °C (storage −40 to 70 °C)
CalibrationEvery meter water-calibrated, with traceable calibration certificate
ComplianceCE, UL, CSA, MCERTS (UK)
SoftwareOptional PanaViewPlus PC software

Stated accuracy applies to a fully developed flow profile (typically 10 pipe diameters of straight run upstream and 5 downstream) and depends on the fluid, temperature and pipe condition.

Transducer options

  • C-AT (0.5 / 1 / 2 MHz, IP68) – standard clamp-on transducers for pipes from DN 50
  • C-RS and submersible C-RS SUB (IP68) – also for pits and flooded areas
  • C-RS HT – for fluid temperatures up to 230 °C
  • CF-LP and CF-JR – for small pipes DN 15 to DN 50
  • Transducer cables from 3 to 90 m

For temporary and spot measurements we recommend the portable Panametrics TransPort PT900.

Panametrics AquaTrans AT600 clamp-on transducers installed on a wastewater pipe

Applications and solutions with the AT600

Real-world applications of the AquaTrans AT600 flow meter from Panametrics:

All AT600 applications in Applications and Solutions »

Why buy the AT600 from INTECH CONTROL

INTECH CONTROL is the official sales, technical and service representative of PANAMETRICS in Slovakia and Hungary. We help you select the right transducers and outputs for your pipe and control system, deliver the instrument, commission it and provide service and calibrations.

Have a specific measurement task? Send us the fluid, pipe size and material, temperature and required outputs – we will propose the right AT600 configuration.

Send an inquiry Datasheet (PDF) All contacts

Technical data: Panametrics datasheet PANA001DS Rev. 12 (06/2026) — © Panametrics LLC. Prepared by INTECH CONTROL, the official Panametrics representative in Slovakia and Hungary.

Top